Sektionaltor mit Schlupftür vs. separatem Eingang
A sectional door with wicket door gives people a smaller entrance within the main door leaf. It is worth considering when staff need occasional access while the large door stays closed and a suitable pedestrian route can reach that opening. A separate entrance becomes more attractive when people need to move independently of vehicle-door operation.
Die Tore SEPPES wicket garage door configuration combines sectional panels with integrated pedestrian access. For a warehouse or workshop, the purchasing question is how that arrangement compares with a conventional sectional door plus a separate pedestrian door. Compare the routes, usable opening, controls and building work before comparing prices.
Inhaltsverzeichnis
UmschaltenStart with the route people actually need
Map where people approach the doorway, where they wait and where they go after passing through. Include shift changes, visits carrying tools and occasions when forklifts are working nearby. A daily headcount alone misses short periods when several people and vehicles reach the same location.
The practical distinction is independence. When the sectional door opens, its integrated wicket moves with the panels and no longer provides a separate doorway at floor level. A wall-mounted pedestrian entrance can remain available while the main door operates, provided its approach and exit are kept clear and separated from vehicle movements.
UK HSE guidance recommends separate pedestrian routes and separate doors for people and vehicles. Use that principle when assessing the layout; simply fitting a smaller door inside a vehicle entrance does not establish that the approach route is separated. HSE pedestrian guidance.
| Site condition | Integrated wicket worth evaluating | Separate entrance worth evaluating |
|---|---|---|
| Personnel access while the main door stays closed | Can avoid raising the full door for suitable visits | Provides the same basic benefit through another opening |
| People need access during vehicle-door operation | Requires a different route or a managed waiting arrangement | Can support an independent route if positioned appropriately |
| Little usable wall space beside the opening | Avoids requiring an additional wall opening at that location | Requires a feasible location and any associated building work |
| Regular movement of carts or bulky items | Clear width, threshold and swing need close review | Can be specified around the actual pedestrian and trolley route |
For a busy shared doorway, start by evaluating an independent pedestrian route. Consider an integrated wicket where the traffic study supports its use. The smaller initial construction scope should not be the only reason for accepting a layout that causes repeated waiting or route conflicts.
Specify the wicket door clear opening and threshold
The wicket door clear opening is the space people can actually use after the frame, leaf position and projecting hardware are considered. Ask for a drawing showing clear width and height at the intended opening angle. A catalogue size or the dimensions of the outer frame should not be substituted for those measurements.
Review the largest routine item carried through the opening, not just a person standing upright. Toolboxes, cleaning equipment and protective clothing can change how people move. If carts are expected, record their width and wheel arrangement and ask the supplier to confirm the proposed passage and threshold detail against that use.
The wicket door threshold needs its own drawing: height above the finished floor, profile across the opening and the floor transition on both sides. Request the exact offered design. Words such as “low threshold” do not identify a dimension, and a photograph cannot establish suitability for a particular cart or accessibility requirement.
Check the swing area and approach space at the same time. Handles, closers and access devices must remain usable without forcing someone into a vehicle route. If the opening will form part of an escape route or an accessible entrance, obtain project-specific confirmation from the responsible designer and relevant approving authority; ordinary pedestrian convenience does not establish those functions.
Treat the wicket door interlock as part of the complete system
A wicket door interlock connects the pedestrian leaf condition with permission to operate the main door. SEPPES describes an arrangement that prevents the large door from opening when the small door is not fully closed. Ask for this function to be identified in the actual configuration and commissioning scope. SEPPES sectional door details.
A card reader or electric lock performs a different job: it controls who can enter. Its presence does not establish that main-door movement is correctly inhibited. Request a description of the monitored condition, the response to an unavailable signal and how the operator indicates that the wicket is preventing movement.
Ask the supplier and installer to agree functional checks for the complete assembly, including the offered access-control options and power-restoration behaviour. These checks should follow the supplier’s instructions and be recorded at handover. A buyer can specify the required outcomes without prescribing a wiring design or bypassing protective functions.
This system-level review matters because safety depends on how the components are combined and configured in the actual installation, as explained in HSE-Leitfaden zu kraftbetätigten Toren und Schranken. A switch listed in a quotation is one component of that arrangement.
Compare the cost of a sectional door with wicket door
A sectional door with wicket door may reduce full-door operation for personnel-only visits. Estimate that benefit from current practice. Count visits that would otherwise require a complete opening and closing, excluding visits made while the main door is already open or several people passing together during one opening.
For example, assume 40 such full-door cycles per working day and 250 working days. That gives 10,000 potentially avoidable cycles per year if those visits can all use the wicket under the agreed operating arrangement. This is an illustrative activity calculation, not a SEPPES life-extension claim or a quantified energy-saving result.
A separate pedestrian door can avoid those same personnel-related full-door cycles. The benefit therefore does not, by itself, decide between the two arrangements. Compare it with independent availability, any extra walking distance and the effect of peak traffic. If the large door is normally held open for long periods, revisit whether either proposal changes that practice.
For the integrated option, include the complete sectional-door assembly, wicket hardware, monitoring, access control, installation and commissioning. For the separate option, include the main door, pedestrian door set, any new wall opening and support, finishing, services relocation and the approach route. Identify which costs are confirmed and which require a building survey.
Include maintenance access and route availability during repairs. A separate entrance may preserve a personnel route during some main-door work, but only if the work area does not obstruct it. With an integrated wicket, main-door repairs may affect both functions. Ask both bidders to explain planned maintenance access and support for the quoted hardware.
Request a wicket door quotation that resolves the choice
A useful wicket door quotation starts with a site plan, photographs, main-door dimensions and a short traffic record. Add whether people must pass during vehicle movements, what they carry, required clear passage, preferred swing direction and any access-control or designated-route requirements.
Request a drawing of the wicket door clear opening and threshold, the proposed monitored functions, a component schedule and a complete installation scope. Where a separate entrance is feasible, obtain a comparable alternative with its building work and pedestrian route included. Mark any assumptions that still require a survey.
Sie können send SEPPES your drawings and access requirements to discuss the integrated configuration. Choose a sectional door with wicket door when the route and operating arrangement support it; choose a separate entrance when independent access justifies the additional works. The final quotation should make that operational trade-off visible to both purchasing and facilities teams.